ISO 9001 CERTIFIED MANUFACTURER IN-HOUSE GRINDING · COATING · INSPECTION

Precision: What sets drilled hole accuracy

Hole size is the sum of tool diameter, runout, machine stability, workpiece movement and thermal growth. Increasing the accuracy of the tool alone has little...

4 min read 725 words Updated 2026-04-01
Pin gauges and a micrometer beside a drilled part on an inspection cloth — Precision: What sets drilled hole accuracy

DC326 tools offer high accuracy because they are made from carbide with hardness ranging from 89 to 93 HRC and thermal conductivity between 80 and 100 W/(m·K). This material minimizes heat buildup, reducing thermal expansion during machining. With a precise geometry that includes a shank diameter of 3.2 mm and drill diameters from 0.04 to 3.17 mm, the DC326 series maintains dimensional stability. The uncoated surface allows for consistent chip evacuation, further enhancing hole quality. Accurate drilling relies on minimizing deviations, making DC326 ideal for applications where precision is critical.

What the specification constrains

The DC326 tool's specification limits its physical dimensions precisely but does not address holder quality or machine stability. The shank diameter is set at 3.2 mm for all sizes. Tool diameters range from 0.04 mm to 3.17 mm, ensuring consistency across the series. This range accommodates various drilling tasks with uniform performance standards. Runout and thermal growth are not controlled by the DC326 specification; these factors depend on external equipment and conditions.

Machine setup and workpiece stability significantly affect hole accuracy beyond tool precision. Hole size calculation includes the sum of tool diameter, runout, machine stability, workpiece movement, and thermal expansion effects. Improving only the tool tolerance has limited impact if other variables are less controlled. Thus, while DC326 tools provide high accuracy through material properties, achieving precise holes also requires careful consideration of additional manufacturing factors.

SpecificationValue
Shank diameter3.2 mm
Diameter1 mm
Carbide hardness89–93 HRC
Series diameter range0.04–3.17 mm

How the number is measured

The hole diameter accuracy is measured using a coordinate measuring machine (CMM) with sub-micrometre precision. The CMM measures the diameter at multiple points around the hole's circumference for consistency. At least five measurements are taken from different angles to ensure repeatability and eliminate any single measurement errors. The tool is inserted into a standardised holder before measuring, maintaining consistent conditions each time. The datum used is the nominal tool size provided by the manufacturer specifications.

This ensures all tools of the same model produce comparable results under controlled conditions. Measurements are taken at room temperature to avoid thermal expansion effects. For this process, the CMM measures holes drilled in a standard material, typically steel or aluminium alloy. Each test piece undergoes surface finish evaluation before accuracy measurement begins.

What moves the number

Carbide's hardness range from 89 to 93 HRC ensures the DC326 tool maintains its shape under cutting forces. High thermal conductivity between 80 and 100 W/(m·K) minimizes heat buildup during machining.

Heat can cause workpiece expansion, which leads to larger holes than intended if not controlled properly. Tool wear also contributes to hole size deviation over time. Shank diameter of 3.2 mm provides consistent holding in the machine collet. Small variations in holder runout exceed typical tool tolerance limits easily. Proper alignment and rigid setup reduce movement affecting final hole accuracy.

Holding it in production

To achieve consistent hole accuracy during production, monitor holder runout regularly. Use a precision instrument that measures deviation under operating conditions. Record any changes in machine stability or workpiece movement over time. Thermal growth can affect hole size; track ambient temperature variations closely. Adjust clamping force on the tool to minimize deflection and maintain alignment.

Maintain detailed records of each production batch, including holder runout measurements. Document deviations from standard operating temperatures for thermal compensation. Compare recorded data with target hole dimensions to identify trends. Adjust setup parameters as needed based on observed patterns and changes. This process ensures that hole accuracy remains within specified limits throughout production runs.

Frequently asked

How does carbide hardness affect hole accuracy?

Carbide hardness ranges from 89 to 93 HRC, providing wear resistance that maintains hole size over extended use. However, achieving precise holes depends more on reducing runout and improving machine stability.

What role does thermal conductivity play in drilling accuracy?

Thermal conductivity of carbide is between 80 and 100 W/(m·K), helping dissipate heat during cutting. Yet, accurate holes require minimizing workpiece movement and ensuring stable machine operation.

Why doesn't using a DC326 tool guarantee hole precision?

While the DC326 series offers high accuracy with diameters from \(0{.}04\) to \(3{.}175\) mm, achieving precise holes also needs low holder runout and stable machining conditions.

Data behind the text

Dimensions and part numbers referenced here come from the TONNY production catalogue. Open the series or diameter index to check a specific record before ordering.

Browse series   Diameter index